Inför tenta medicinsk mätteknik

Övningen är skapad 2024-01-07 av LineEH. Antal frågor: 93.




Välj frågor (93)

Vanligtvis används alla ord som finns i en övning när du förhör dig eller spelar spel. Här kan du välja om du enbart vill öva på ett urval av orden. Denna inställning påverkar både förhöret, spelen, och utskrifterna.

Alla Inga

  • systemic vascular resistance SVR
  • central venous pressure CVP
  • korotkoff Sounds heard while measuring blood pressure
  • oscillometric Pressure pulses/fluctuations detected by an automated blood pressure cuff
  • thermodilution Cardiac output measurement with a temperature indicator injected
  • pulse pressure method Estimate CO by analyzing the arterial pressure waveform (pulse pressure), non invasive
  • impedance cardiography a non-invasive technique used to measure hemodynamic parameters with impedance changes
  • lithotripsy a medical procedure used to break down kidney stones
  • extracorpereal shock wave lithotripsy ESWL
  • pulsed dye laser lithotripter with laser
  • electrohydraulic lithotripter using shockwaves/plasma formation to break kidney stones
  • Einthoven I, II, III the bipolar extremity leads
  • aVR, aVL, aVF unipolar extremity leads
  • precordial leads Placed on specific locations on the chest according to a standardized pattern (V1 to V6).
  • implantable cardioverter defibrillator ICD
  • monophasic, biphasic Two types of defibrillation waveforms
  • pneumatics The use of gas flowing under pressure to transmit power from one location to another
  • zeolit absorption, elektrolysis, destillation Manufacturing of O2
  • enfluorane, sevofluorane Anestetic Compounds with diffucult names, used today
  • anelgetic bedövande/smärtstillande på engelska
  • blood volume sensor BVS
  • continuous ambulatory peritoneal dialysis CAPD (dialysis)
  • automated peritoneal dialysis APD (dialysis)
  • automatic exposure control AEC
  • non-normal incidence, scattering, diffuse reflection Reflections of ultrasound waves
  • matching layer the component of the transducer that is used to step down the impedance from that of the element to that of the patient's skin
  • backing layer behind the piezoelectric elements. Its primary role is to absorb and dampen US waves
  • dynamic focusing adjusting the focal point of an ultrasound beam in real-time during imaging.
  • beamformer is a crucial component of the ultrasound system responsible for controlling and shaping the ultrasound beam transmitted by the transducer
  • apodization adjusting the amplitude or shape of the electrical signals sent to the individual elements of an ultrasound transducer.
  • dynamic aperture makes sound beam narrower over a greater range of depths and optimize lateral resolution.
  • time-gain control TGC
  • dynamic range refers to the range of signal intensities that an ultrasound system can detect and display
  • harmonic imaging the creation of an image from sound reflections at twice the frequency of the transmitted sound
  • dynamical receive focus adjusting ultrasound beam focus during reception for better imaging, measure on different depth
  • parallel beamforming processing multiple ultrasound beams simultaneously
  • demodulation extracting information or signals of interest from the raw echo data received by the transducer
  • maximum likelihood expectation maximization MLEM
  • ordered-subset expectation maximization OSEM
  • baysian penalized likelihood algorithm BPL, reconstruction method with penalty factor
  • dual-energy-window A method in imaging using two energy windows to enhance accuracy
  • triple-energy-window A technique in imaging employing three energy windows for better accuracy
  • time of flight TOF (PET)
  • cone-beam distortions in CT images due to cone-shaped X-ray beams
  • beam hardening increased average energy of an X-ray beam as it passes through an object, resulting in selective absorption and artifacts in imaging.
  • filtered back-projection FBP
  • dual energy/dual source two sources of X-ray beames instead of one
  • photon counting CT Spectral CT - More energy levels can be detected instead of the mean energy
  • cone beam computed tomography CBCT
  • CT dose index CTDI
  • dose length product DPL
  • sound pressure level SPL (Audiometry)
  • sound intensity level SIL (Audiometry)
  • tympanometry placing a probe in the ear canal and measuring middle ear function
  • electrophysiological audiometry measures electrical signal in the brain during stimuli (Audiology)
  • audiogram A graphic representation/record of hearing
  • impedance audiometry investigate the middle ear function by checking the mobility of the eardrum. Tympanometry is a test to test this
  • impedance, psychoacoustic, electrophysiological Audiometry is divided into
  • stapedius muscle reflex in middle ear, measure pressure changes
  • pure tone audiometry look for the person's thresholds that are both air-conducted and bone conducted.
  • psychoacoustic audiometry the patient needs to tell if they hear or not. This task may pose challenges for younger children
  • otoacoustic emmisions OAE (audiology), are sounds generated by the inner ear, specifically by the hair cells in the cochlea, in response to external stimuli, like sounds or clicks
  • auditory brainstem response ABR (audiology), measurable responses in the brainstem to a series of acoustic stimuli
  • auditory steady state response ASSR, measured by evaluating ongoing activity of the brain in response to a change in stimulus
  • conductive, sensorineural, retrocochlear Types of hearing loss
  • tonotopy Frequency specific maximal amplitude at the basilar membrane, are processed in distinct locations
  • auditory processing disorder APD hearing disorder
  • surgery, technology, strategies Hearing loss (re)habilitation can be divided into
  • bone-anchored hearing aids • Vibrations to the inner ear • Titanium implant behind the ear • Gain on the basis of the audiogram
  • image intensifiers II (digital radiology)
  • flat panel detector FPD (DR)
  • charged coupled device CDD (DR)
  • semiconductor Direct conversion (DR) uses
  • scintillator indirect conversion uses a ... and CCD
  • last image hold LIH (DR)
  • time of echo TE
  • repetition time TR
  • monochromatic, coherent, collimated laser light properties
  • thermal, blast, photoablation, photochemical Tissue effects of laser
  • photodynamic therapy PDT (lasers)
  • optical coherence tomography OCT (laser)
  • time domain TD (-OCT)
  • spectral domain SD (-OCT)
  • swept source SS (-OCT)
  • hyperspectral imaging White light source, hyperspectral camera with a prism
  • diffuse reflectance spectroscopy illuminates the tissue with a light, and then detects it at a distance from the source.
  • photoacoustical imaging utilizes both light and sound to generate images.
  • gross tumor volume GTV (radiation therapy)
  • planning target volume PTV (radiation therapy)
  • intensity modulated radio therapy IMRT (radiation therapy)
  • volumetric modulated arc therapy VMAT (radiation therapy)
  • low-dose rate LDR (radiation therapy)
  • high-dose rate HDR (radiation therapy)

Alla Inga

Utdelad övning

https://glosor.eu/ovning/infor-tenta-medicinsk-matteknik.11861815.html

Dela